What is on the free journeyman plumber practice test?

Six real open-book questions covering the code areas the exam draws on — drainage slope, trap seal depth, vent terminal height, water heater T&P discharge, water supply fixture units and cleanout distance — each with the correct answer and the IPC article or table it comes from. No account is needed to work through all six.

These 6 sample questions represent the type of questions you will encounter on the US Journeyman Plumber exam — open book against the International Plumbing Code (IPC), with both the knowledge and calculations sections testing your ability to find and apply code rules, not to memorize them.

Click the Show Answer button under each question to see the correct answer, a detailed explanation, and the code reference. Use these questions to practice your code-navigation skills — chapter map, section numbering, and the index — and to identify areas that need more study.

PlumberPractice covers the exam content of the US journeyman plumber exam — IPC code navigation and calculations. Sign up for free to start with the first chapter of each exam part in your state.

1Drainage Slope · IPC 704.1

What is the minimum slope for a horizontal drainage pipe 3 inches or smaller?

  • 1/8 inch per foot
  • 1/4 inch per foot
  • 1/2 inch per foot
  • 1 inch per foot
▶Show Answer

✅ Correct Answer: 1/4 inch per foot

IPC Table 704.1 requires 1/4 inch per foot for pipes 3 inches and smaller; 4 inches and larger may use 1/8 inch per foot.

Reference: IPC 704.1 · Table 704.1

2Trap Seal · IPC 1002.2

What is the required water seal depth for a plumbing trap?

  • 1 inch minimum
  • 2 to 4 inches
  • 4 to 6 inches
  • 6 inches minimum
▶Show Answer

✅ Correct Answer: 2 to 4 inches

Every trap must have a liquid seal of not less than 2 inches and not more than 4 inches to block sewer gas.

Reference: IPC 1002.2

3Vent Terminal · IPC 905.4

A vent terminal through a roof must extend at least how far above the roof?

  • 3 inches
  • 6 inches
  • 12 inches
  • 24 inches
▶Show Answer

✅ Correct Answer: 6 inches

Vent terminals must extend at least 6 inches above the roof, measured from the highest point of penetration.

Reference: IPC 905.4

4T&P Discharge · IPC 504.6

Where must the T&P relief valve discharge pipe terminate?

  • Into the sewer
  • 6 to 24 inches above the floor
  • At the ceiling
  • Connected to the cold water inlet
▶Show Answer

✅ Correct Answer: 6 to 24 inches above the floor

The discharge pipe must terminate 6 to 24 inches above the floor with no threads and no shutoff valve.

Reference: IPC 504.6

5Fixture Units · IPC 604.3

A dwelling bathroom group (lavatory, water closet, tub/shower) adds approximately how many water supply fixture units?

  • 4 WSFU
  • 6 WSFU
  • 8 WSFU
  • 10 WSFU
▶Show Answer

✅ Correct Answer: 6 WSFU

A private bathroom group counts as about 6 water supply fixture units under the IPC fixture unit tables.

Reference: IPC 604.3 · Table E103.3(1)

6Cleanouts · IPC 707.2

A cleanout is required at the base of a soil stack and within what distance of the building sewer connection?

  • 5 feet
  • 10 feet
  • 20 feet
  • 50 feet
▶Show Answer

✅ Correct Answer: 10 feet

Cleanouts are required at the base of each stack and within 10 feet of the building sewer connection on the building drain.

Reference: IPC 707.2

Journeyman plumber practice test — questions

Is the free journeyman plumber practice test really free?
Yes. All six sample questions are open with no account: click Show Answer under a question to see the correct option, the explanation and the IPC reference. A free account then opens the first chapter of each exam.
What kind of questions are on the free journeyman plumber practice test?
Six open-book questions in the same style as the exam: drainage slope (IPC 704.1), trap seal depth (IPC 1002.2), vent terminal height (IPC 905.4), T&P relief valve discharge (IPC 504.6), water supply fixture units (IPC 604.3) and cleanout distance (IPC 707.2).
Is the journeyman plumber exam open book?
Yes. The US journeyman plumber exam this platform prepares for is open book on the International Plumbing Code (IPC). The knowledge and calculations questions test your ability to find and apply the rule, not to memorise it.
How do I get more journeyman plumber practice questions?
PlumberPractice draws on one shared approved IPC bank of 1,300+ questions across the content areas each state outline names, with full-length timed simulations at the state’s own item count and time limit and an AI tutor that explains every answer.

Preparing state by state? See the journeyman plumber exam formats for Colorado, Georgia, Oklahoma, Utah and Vermont, or follow the 30-day study checklist.

Ready for the Full Question Bank?

Get unlimited access to IPC-style open-book practice questions across both exam lines — IPC code navigation and calculations — with adaptive difficulty, timed simulations, AI Tutor explanations, and detailed progress tracking.

📥 Get 6 Free IPC Practice Questions